Technical Information
Colour : White
Appearance : Emulsion
Thermal Conductivity : 0.029 w / m K
Elongation : >100%
Specific Gravity : 1.03
Surface Dry : 30 mins.
Coverage : 3 sq.m per litre per coat
PACKING
1 & 20 litre
Area Of Application:
- Concrete, metal, fibre or timber surfaces
- Roofings of residential & commercial complexes
- Cold storages
- Fuel & water tanks.
Method of Application
SURFACE PREPARATION
- Surface must be clean & sound, free from all dust, oil, grease & other contaminants. Remove all loose material with
scrapper or stiff broom
- Degrease the metal surface by washing down with detergent & prime all bare timber with wood primer.
- Fill all the cracks up to 5 mm width with DR. FIXIT CRACK-X PASTE or with DR. FIXIT PIDICRETE URP modified mortar
incase of width more than 5 mm on cementitious substrates
- If the substrate temperature is high then cool it down by using water hose and allow the substrate to attain a saturated
surface dry condition.
APPLICATION PROCEDURE
PRIMING
- For cementitious substrates, it is important to apply DR. FIXIT PRIMESEAL diluted with water in 2:1 ratio depending upon
the porosity and condition of the substrate.
- Over G I sheet metal roofs, priming is not necessary.
APPLICATION
- Apply 2 coats of DR. FIXIT HEATSHIELD directly from the container, without thinning, over the primed surface. Stir well
before use.
- DR. FIXIT HEATSHIELD can be applied on a prepared cementitious, metal or timber surface with an interval of 2 hrs.
- On metal surfaces, prime the surface with an anti-corrosive primer
- Depending on the porosity of surface, 1 litre can cover 3 sqm for one coat. Apply 3 coats to achieve a minimum DFT
of 400 microns for optimum performance.
|
|
|
Application of Dr. Fixit Heatshield on a Sloping Metal Surface |
|
|
| |
|
|
Precautions & Limitations
- Do not apply DR. FIXIT HEATSHIELD when temperature is below 10°C and above 40°C.
|