Technical Information
Nature : Single component.
Appearance : Emulsion (Available in White & Dark bases)
Specific Gravity : 1.29
Coverage : 35 sq.ft/lt. for 2 coats
Coating Thickness : 110 microns DFT for 2 coats
Elongation (250 micron DFT) : >200% (Typical Value at 30°C)
Re-coating period : Min. 5 hrs (at 30°C)
Method of application : By brush, roller or spray
Adhesion on
Cementitious substrate - Excellent
Asbestos - Excellent
PACKING
1 & 20 litre
Area Of Application:
- Exterior surfaces of RCC, concrete panels, plastered masonry walls.
Method of Application
SURFACE PREPARATION
- Surface for treatment must be thoroughly cleaned of all laitance, loose material, oil, grease etc
- Mechanical means such as wire brushing, shot blasting can be used, and finally vacuum clean all loose solids
and liquids if required.
- All surface cracks up to 5 mm width should be filled up with DR. FIXIT CRACK-X range products.
- The cracks more than 5 mm wide and all separation gaps should be filled up with DR. FIXIT PIDICRETE URP
modified mortar or as specified.
APPLICATION PROCEDURE
|
|
|
Application of Dr. Fixit Primeseal |
Primed Exterior Surface |
Application of Dr. Fixit Raincoat |
| |
|
|
Precautions & Limitations
- Do not dilute DR. FIXIT RAINCOAT by any means.
- Application of a primer is must for all types of surfaces.
- Excess water on substrate prior to application must be removed by suitable means.
- Do not apply below 10oC or above 45oC
- Do not apply during rains, or in direct sunlight
- The covering capacity of DR. FIXIT RAINCOAT can vary as per the nature of the substrate.
|
Download |
|