Technical Information
Pot life
|
: |
45 minutes at 30oC |
| Specific gravity |
: |
1.01 ± 0.02 |
| Compressive strength |
: |
80 N / mm2 at 7 days |
| Tensile strength |
|
45 N / mm2 at 7 days |
| Bond strength |
|
16 N / mm2 at 2 days moist cure |
| Application temperature |
|
50C to 35OC |
| Shelf life |
|
: 12 months when stored in dry cool storage |
Packing
Areas of Application
- For repairs, rehabilitation of structural members
- To fill up cracks in roof slab, RCC walls and other structural members
- For strengthening of RCC members in repairs
Method of Application
- Identify the locations for grouting
- Drill and fix nozzles with suitable material. Allow to set for 24 hours
- Mix two components of Dr. Fixit Epoxy Injection Grout ( base & hardener) thoroughly till homogeneous mix is obtained
- Using grouting pump, start grouting Epoxy Injection Grout with desired pressure.
- Pressure can be adjusted at site depending upon the type of RCC structure and the nature of problem.
Precautions & Limitations
- Use mixed material within pot life period.
- Do not grout at closed spacing at a time. Stagger the location of grout for convenience.
- Handle Dr. Fixit Epoxy Injection Grout with gloves
- All tools and tackles should be cleaned with an Epoxy Solvent before its pot life period has expired.
- Any contact with skin should be washed with plenty of water and soap, splashes in the eyes should be washed with plenty of water
and immediate medical advice should be taken.
|
Download |
|